Evaluation of Bacterial Contamination of Water Supply in Dental Unit Water Lines at Shahroud Dental Offices 2015
DOI:
https://doi.org/10.22100/jkh.v11i1.1132Keywords:
Shahroud, Biofilm, Dental unit waterAbstract
Introduction: Assessment of microbial contamination in dental unit waterlines has been focused on because of high risk of dangerous infections in immunocompromised patients. The purpose of this study was to evaluate the bacterial contamination of water supply in dental unit water lines at Shahroud dental offices.
Methods: In this descriptive analytical study we investigated 560 water samples collected from four parts of each unit including air/water syringe, turbine hand piece (before &after flushing), cup filler and 2 water sample collected from city water reservoir in Shahroud dental office during 2015. Water samples were taken on Saturdays (the first working day in a week) and Thursday (the last working day in a week), before and after treatment on the same units.
Samples were transported in closed sterile containers to microbiology laboratory. All samples were incubated on blood agar and McCaskey plates for 72 hours at 37°C. Bacterial contamination was then evaluated. All samples were analyzed for legionella. Data were analyzed by ANOVA and t-test.
Results: Total mean bacterial count was 4671 cfu/ml. Mean bacterial contamination on Saturdays (6320 cfu/ml) were higher than Thursdays (3860 cfu/ml). Mean bacterial contamination before treatment was (4050 cfu/ml) less than the end of treatment (6250 cfu/ml) on the same unit. Mean bacterial contaminations of self-Dental Office was higher than other clinics
Conclusion: The result of this study demonstrated that microbiological level of dental unit waterlines is high. The dentists must be aware of the high level of microorganisms in the dental unit’s water and thus minimize the risk of infection in both staff and patients.
References
Parsaie A, Jazayeri F, Taherian Mand Yazdani S. Infection control in dentistry] Persian. 1st ed. Tehran: Bahman pub;1996.p.2.
Szymans KJ. Control methods of the microbial water quality in dental waterlines. Ann Agric Environ Med 2003;10:1-4.
al Shorman H, Nabaa LA, Coulter WA, Pankhurst CL, Lynch E. Management of dental unit waterlines. Dent Update 2002;29:292-8.
Shearer BG. Biofilm and the dental office. J Am Dent Assoc 1996;127:181-9.
Fiehn NE, Larsen T. The effect of drying dental unit waterline biofilms on the bacterial load of dental unit water. Int Dent J 2002;52:251-4.
Montobugnolis L, Chersoni S, Prati C. A between- patient disinfection method to control water line contamination and biofilm inside dental unit. J Hosp Infect 2004;56:297-304.
Memarian M, Fazeli MR, Jamalifar H, Karami S. Microbial evaluation of dental units waterlines at the department of operative dentistry, Tehran University of Medical Sciences in the year 2006. Teh Dent Sch 2008;21:65-71.[Persian].
Abel LC, Miller RL, Micik RE, Ryge G. Studies on dental aerobiology. IV. Bacterial contamination of water delivered by dental unit. J Dent Res 1971;50:1567-9.
McEntegart MG, Clark A. Colonyzation of dental units by water bacteria. Br Dent J 1973; 134:140-2.
Whitehouse Rl, Peters E, Lizotte J, Lilge C. Influence of biofilms on microbial contamination in dental units water. J Dent 1991;19:290-5.
Williams HN. Contribution of biofilm bacteria to the contamination of the DUWS. J Am Dent Assoc 1995;126:1255-60.
Teixeira RM. Water quality of westbrabantse dental units and the effect flushing. Ned Tijdschr Tandheelkd 2002;109:307-11.
Samyari H, Jalayer T, Asadian H. Infection control in dentistry.1st ed. Tehran: Azma pub;2004.p.125.[Persian].
Samyari H, Jalayer T, Asadian H. Infection control in dentistry. 1st ed. Tehran: Azma pub;2004.p.125.[Persian].
Pankhurst CL, Philpoott-Howard J. Microbiological quality of water in dental chair unit. JH os Inf 2004;23:167-74.
Ghaem Maghami A, Mehdipour M, Goudarzi H. The rate of bacterial contamination in dental units water supply at shahid beheshti dental school-2000. J Beheshti Univ Dent 2003;21:73-81.[Persian].
Taheri JB, Oliya P, Olomi K. Bacterial contamination level of water supply in dental unit at Shahid Beheshti dental school-1999. J Beheshti Univ Dent 2003;21:103-9.[Persian].
Szymanska J, Wdowiak L, Puacz E, Stojek N. Microbial quality of water in dental unit reservoirs. Ann Agric Environ Med 2004;11:355-8.
Sacchetti R, Baldissarri A, De Luca G, Lucca P, Stampi S, Zanetti F. Microbial contamination in dental unit waterlines: comparison between Er: YAG laser and turbine lines. Ann Agric Environ Med 2006;13:275-9.
Walker J, Bradshow D, Bennet A, et al. Microbial biofilm formation and contamination of dental-unit water systems in general dental practice. Appl Environ Microbiol 2002;66:3363-7.