The Effect of Foot Orthoses on Energy Consumption in Runners with Flat Feet
DOI:
https://doi.org/10.22100/jkh.v5i1.151Keywords:
Energy consumption, Foot orthosis, Flat FootAbstract
Introduction Foot orthosis is used as protective treatment in people with flatfoot. This study aimed at assessing the effects of Foot orthosis on energy consumption in 20 runners with flat feet.
Methods: In this study a treadmill and a Quark b2 were used to measure oxygen consumption. For each patient, a pair of foot orthosis with the appropriate size was prepared. The maximum running Heart rate, vo2 max and vo2 of the subjects were measured and calculated with and without foot orthoses. The data were compared through paired T-test.
Results: In this study, after using the foot orthoses, the mean VO2 (ML/M), theVO2 max (ML/M for each Kg of body weight) and the maximum heart rate respectively reduced from 4504.6 to 4488.3, from 63.6 to 63.4 and from 168.7 to 168.0, all of which indicating a significant observed reduction (P<0.05).
Conclusion: Foot support devices (orthoses) result in realignment of lower extremity joints in patients with flat feet, thus length- tension relationship of muscles improve. This prevents muscle fatigue in long- distance running. Finally, when suitable foot orthoses was applied energy consumption during running decreased.
References
Cavangh PR, Rodgers MM. The arch index: a useful measure from footprints. J Biomech 1987;20(5):547-51.
Van Boerum DH, Sangeorzan BJ. Biomechanics and pathophysiology of flat foot. foot Ankle Clin 2003;8(3):419-30.
Lee MS, Vanore JV, Thomas JL, Catanzariti AR, Kogler G, Kravitz SR, et al. Diagnosis and treatment of adult flatfoot, J Foot Ankle Surg 2005;44(2):78-113.
Sokhangoei Y, Asgari Ashtyani AR. Medical Shoe. Tehran: Sarmadi pub;2005.p.47-51.[Persian].
Nawoczenski DA, Ludwig PM. Electromyographic effects of foot orthotics an selected lower extremity muscles during running. Arch Phys Med Rehabil 1999;80(5):540-344.
Noll KH. The use of orthotic devices in adult acquied flatfoot deformity. Foot Ankle Clin 2001;6(1):25-36.
Anne M. James MW. Foot arthoses affect freyuency comtonrnts of muscle activitiy in the lower extremity. Gait & Posture 2006;23(3):295-302.
Williams DS, Mcclay IS. Measurement used to characterize the foot and medial Longitudinal arch: reliability and validity. Phys Ther 2000;80(9):864-71.
Gottschall JS, Kram R. Energy cost and muscular activity required for propulsion during walking. J Appl Physiol 2003;94(5):1766-1772.
Fax LF, Matias LK. Exercise physiology. Translated to Persian by: Khaledan A. Tehran: Tehran University pub;2000.p.82-84,90-97.
Taylor JH, kastil DL. Sport injuries. Translated to Persian by: Rahmaninia F, Moeeni Z, Salami F. Tehran: Mobtakeran pub;2005.p.70-95.
Hennacy Rl. Metabolic Efficiency of orthotic appliances measured by oxygen consumption. J Am Pediatry Assoc 1973;63(10):481-490.
Bergg K, Sady S. Oxygen cost of running at submaximal speeds while wearing shoe inserts. Rese Q Exerc Sport 1985;56(1):86-89.
Otman S, Basgoze O, Gokee- kustal Y. Energy cost of walking with flat feet. Prosthet Orthot Int 1988;12(2):73-6.
Downloads
Published
Issue
Section
License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.