Estimation of Aerobic Capacity (VO2-max) and Physical Work Capacity in Laborers

Authors

  • Sedeghe Hosseinabadi
  • Peiman Hamidi Bagejan
  • Hossein Ebrahimian
  • Abdollah Barkhordari
  • Tahere Raei Bandpe

DOI:

https://doi.org/10.22100/jkh.v8i3.34

Keywords:

Aerobic capacity, Physical work capacity, Worker, Rolling tube

Abstract

Introduction: Measurement of Maximum aerobic capacity (VO2-max) is important in physiologically fitting the laborers to the job. This study was conducted to estimate the aerobic capacity and physical work capacity (PWC) of workers of galvanize department of Semnan rolling pipe Company and also determine the relative frequency of workers whom their jobs were proportional to their physical work capacity .

Methods: 50 male workers of Semnan rolling pipe company were selected randomly to participate in this cross-sectional study.  Tuxworth & shahnavaz methods were applied to measure instances VO2-MAX. Independent-Sample t-test and correlation technique were used to analysis the data by SPSS software.

Results: Average maximum aerobic capacity of workers was 2.88± .033 liters per minute and the average of physical work capacity was 4.76 ± 0.54 kilocalories per minute. There was a significant relationship between body mass index and aerobic capacity. The result  showed that 36 percent of  subjects expend  more energy than their physical work capacity to perform their duties during the work time.

Conclusion: According to the ILO classification, the average physical work capacity of the workers fall into a category of light energy;accordingly,  on average, these workers had physical ability to performe less or lighter duties. More than one-third of these workers need to undergo job modification or to change their present job to a job with less energy consumption.

References

Arts FJ, Kuipers H, Jeukendrup AE, Saris WH. A short cycle ergometer test to predict maximal workload and maximal oxygen uptake. Int J Sports Med 1993;14(8):460-4.

Habibi E, Dehghan H, Zeinodini M, Yousefi H, Hasanzadeh A. A study on work ability index and physical work capacity on the base of fax equation vo2 max in male nursing hospital staff in Isfahan, Iran. Int J Preventive Medicine 2012;3(11):776-782.

Malek MH, Housh TJ, Berger DE, Coburn JW, Beck TW. A new non-exercise-based VO2-max prediction equation for aerobically trained men. J Strength Cond Res 2005;19(3):559-65.

Zoladz JA, Duda K, Majerczak J. VO2/power output relationship and the slow component of oxygen uptake kinetics during cycling at different pedaling rates: relationship to venous lactate accumulation and blood acid-base balance. Physiol Res1998; 47(6):427-38.

Choobine A, Tabatabai H, Barzide M. Estimation of aerobic capacity (VO2-max) and study of its associated factors among male workers of industrial factories in sepidan/fars province, 2009. Sci Med J 2011;10(1):1-12.

Vossoughi Sh. Assessment of physical work capacity in health personnel and the protection of man [dissertation]. Tehran University of Medical Sciences;1993.

Valipour F, Khavanin A, Asiliyan H, Pourtaghi Gh. H, Mohebi HA, Jonaidi N, et al. Measurement of physical work capacity (pwc) for iranian military ‎personnel in different condition chamber laboratory clime (Normal and ‎Very Heat Humid).‎ Journal of Military Medicine 2007;9(1):67-72.[Persian].

Motalebi M. Assessment of work ability in workers employed in machining industry and provide appropriate scientific methods for selecting workers for physical work [dissertation]. Tarbyat Modares University;1994.

Tuxworth W, Shahnavaz H. The design and evaluation of a step test for the rapid prediction of physical work capacity in an unsophisticated industrial work force. Ergonomics 1977; 20(2):181-91.

Ainsworth BE, Haskell WL, Leon AS, David R, Jacobs JR, Henry J, et al. Compendium of physical activities: classification of energy costs of human physical activities. Med Sci Sports Exerc 1993;25(1):71-80.

WHO. Physical status: the use and interpretation of anthropometry. Report of a WHO Expert Committee. WHO Technical Report Series 854. Geneva: World Health Organization, 1995.

Olson MS, Willford HN, Blessing DL, Wilson GD, Halpin G. A test to estimate VO2-max in females using aerobic dance, heart rate, BMI, and age. J Sports Med Phys Fitness 1995;35(3):159-68.

Bradshaw DI, George JD, Hyde A, LaMonte MJ, Vehrs PR, Hager RL, et al. An accurate VO2-max nonexercise regression model for 18-65-year-old adults. Res Q Exerc Sport 2005;76(4):426-32.

Petrella RJ, Koval JJ, Cunningham DA, Paterson DH. A Self-Paced step test to predict aerobic fitness in older adults in the primary care clinic. J Am Geriatr Soc 2001;49(5):632-8.

Kline GM, Porcari JP, Hintermeister R, Freedson PS, Ward A, McCarron RF, et al. Estimation of VO2-max from a one-mile track walk, gender, age, and body weight. Med Sci Sports Exerc 1987; 19(3):253-9.

Chaterjee S, Mitra SK, Samanta A. Aerobic capacity of the brick-field workers in eastern India. Ind Health 1994;32(2):79-84.

Betik AC, Hepple RT. Determinants of VO2-max decline with aging: an integrated perspective. Appl Physiol Nutr Metab 2008; 33(1):130-40.

Byars A, Greenwood M, Greenwood L, Simpson WK. The effectiveness of a pre-exercise performance drink (PRX) on indices of maximal cardiorespiratory fitness. J Int Soc Sports Nutr 2006;12(3):56-9.

Klausen K, Andersen C, Nandrup S. Acute effects of cigarette smoking and inhalation of carbon monoxide during maximal exercise. Eur J Appl Physiol Occup Physiol 1983;51(3):371-9.

Virtanen M, Vahtera J, Pentti J, Honkonen T, Elovainio M, Kivimki M. Job strain and psychologic distress influence on sickness absence among Finnish employees. Am J Prev Med 2007;33(3):182-7.